Showing posts with label Dew Point Control & Metering. Show all posts
Showing posts with label Dew Point Control & Metering. Show all posts

Wednesday, June 19, 2013

The Logic Behind The Magic." Gas Dew Point Control and Metering 3".

Metering

The purpose of the flow metering system is to measure the gas flow for commercial purposes.
Sales gas metering package includes the dollowing:
- Flow Metering system
- Gas Chromatograph
- Miscellaneous component, like isolation valve, tube JB, etc.

One of the options is utilizing senior orifice meter. The flow meter is designed and constructed in accordance for AGA Report No 2. To compesate the flow readings, Pressure and Temperature transmitters are provided on each stream.

Monday, June 17, 2013

The Logic Behind The Magic." Gas Dew Point Control and Metering".

Dry gas from TEG overhead KO drum flows to Gas/Gas Exchanger where it is cooled by Low Temperature Separator overhead stream. The Gas/Gas Exchanger is a special Printed Circuit Heat Exchanger design. The exchanger is protected by strainers in order to avoid oversized particles entering Sales Gas Metering Skid.